VENT-FREE GAS
FIREPLACE INSERT
OWNER’S OPERATION AND
INSTALLATION MANUAL
MODEL FBD32RT
PFS
®
US
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable va-
pors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
WARNING: This appliance is equipped for Natural and
Propane gas. Field conversion is not permitted other than
between natural or propane gases.
Questions, problems, missing parts? Before returning to your retailer, call
our customer service department at 1-866-573-0674, 8:00 am - 4:30 pm CST,
Monday through Friday or email customerservice@usaprocom.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 31 32

Shrnutí obsahu

Strany 1 - MODEL FBD32RT

VENT-FREE GASFIREPLACE INSERTOWNER’S OPERATION AND INSTALLATION MANUALMODEL FBD32RTPFS®US WARNING: If the information in this manual is not followed

Strany 2 - TABLE OF CONTENTS

www.usaprocom.com200069-01A10INSTALLATIONNOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary hea

Strany 3 - 3200069-01A

www.usaprocom.com11200069-01AINSTALLATIONGas SelectSelector de gasNGLPNGLPGas InletGas estéGas SelectSelector de gasNGLPNGLPGas InletGas estéFuel Sele

Strany 4 - SPECIFICATIONS

www.usaprocom.com200069-01A12INSTALLATIONBUILT-IN FIREPLACE INSTALLATIONFigure 9 - Rough Opening for Wall InstallationFigure 7 - Clearance to Combusti

Strany 5 - LOCAL CODES

www.usaprocom.com13200069-01AINSTALLATION3. Attach gas line to replace gas regulator. See Connecting to Gas Supply, page 14.4. Check all gas connec

Strany 6 - UNPACKING

www.usaprocom.com200069-01A14INSTALLATIONCONNECTING TO GAS SUPPLY CAUTION: For propane/LP gas, never connect heater directly to the gas supply.

Strany 7 - 7200069-01A

www.usaprocom.com15200069-01ANGLPFigure 12 - Gas Connection* Purchase the optional CSA design-certied equipment shutoff valve from your dealer.For p

Strany 8 - 30,000

www.usaprocom.com200069-01A16Figure 15 - Equipment Shutoff ValveCHECKING GAS CONNECTIONSOpenClosedEquipment Shutoff ValveControl Valve LocationControl

Strany 9 - VENTILATION AIR

www.usaprocom.com17200069-01ATop Trim PieceScrewTop Decorative TrimLeft/Right Decorative TrimLeft Trim PieceRight Trim PieceFigure 18 - Decorative Tri

Strany 10 - COMBUSTIBLES

www.usaprocom.com200069-01A18Figure 21 - Installing LogsINSTALLATIONINSTALLING LOGS WARNING: Failure to posi-tion the parts in accordance with

Strany 11 - GAS SELECTION

www.usaprocom.com19200069-01AINSTALLATIONAAAAAAAAAAAAAAREMOTEOFFONLEARNINSTALLING BATTERIES CAUTION: Do not mix old and new batteries. Do not mix alka

Strany 12 - 200069-01A12

www.usaprocom.com200069-01A2TABLE OF CONTENTSSafety ... 3Specications ...

Strany 13 - CAUTION: Do not operate

www.usaprocom.com200069-01A20OPERATIONFOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol-low these instructions exactly, a re or explos

Strany 14 - CONNECTING TO GAS SUPPLY

www.usaprocom.com21200069-01A10. Press the LEARN BUTTON on the front of the remote receiver box until you hear a beep (see page 21).11. Press the ON b

Strany 15

www.usaprocom.com200069-01A22Key SettingsON - Operates unit to on position, manually operated solenoid ON.OFF - Operates unit to off position, manuall

Strany 16 - CHECKING GAS CONNECTIONS

www.usaprocom.com23200069-01AOPERATION2. Press and hold the SET key until the de-sired set temperature is reached. The LCD screen set numbers will in

Strany 17

www.usaprocom.com200069-01A24INSPECTING BURNERSIMPORTANT: Owner’s should check pilot ame pattern and burner ame pattern often. Incorrect ame patt

Strany 18 - INSTALLING LOGS

www.usaprocom.com25200069-01ACARE AND MAINTENANCE WARNING: Turn off heater and let cool before servicing. CAUTION: You must keep control areas, burner

Strany 19 - INSTALLING BATTERIES

www.usaprocom.com200069-01A26CARE AND MAINTENANCETROUBLESHOOTING WARNING: If you smell gas:• Shut off gas supply.• Do not try to light any appliance

Strany 20 - LIGHTING INSTRUCTIONS

www.usaprocom.com27200069-01AProblem Possible Cause Corrective ActionWhen ignitor button is pressed in, there is no spark at ODS/pilot1. Ignito

Strany 21 - MANUAL LIGHTING PROCEDURE

www.usaprocom.com200069-01A28Problem Possible Cause Corrective ActionBurner(s) does not light after ODS/pilot is lit1. Burner orice is clogged.2. Bur

Strany 22 - OPERATION

www.usaprocom.com29200069-01ATROUBLESHOOTINGProblem Possible Cause Corrective ActionWhite powder residue forming within burner box or on adjacent

Strany 23

www.usaprocom.com3200069-01ASAFETYIMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, op-erate, or service

Strany 24 - BURNER PRIMARY AIR HOLES

www.usaprocom.com200069-01A30PARTSMODEL FBD32RTREMOTEOFFONLEARNTEMP182024222519212623111214161715158413567239101

Strany 25 - MAIN BURNER

www.usaprocom.com31200069-01APARTSMODEL FBD32RTThis list contains replaceable parts for your heater. When ordering replacement parts, follow the instr

Strany 26 - BLOWER (OPTIONAL ACCESSORY)

200069-01Rev. A06/13REGISTER YOUR PRODUCT AT WWW.USAPROCOM.COMIMPORTANT: We urge you to register your product within 10 days of date of installation,

Strany 27 - TROUBLESHOOTING

www.usaprocom.com200069-01A41. Do not place Propane/LP supply tank(s) inside any structure. Propane/LP supply tank(s) must be placed outdoors.2. Thi

Strany 28

www.usaprocom.com5200069-01AQUALIFIED INSTALLING AGENCYOnly a qualied agency should install and replace gas piping, gas utilization equipment o

Strany 29 - REPLACEMENT PARTS

www.usaprocom.com200069-01A6PRODUCT IDENTIFICATIONFigure 1 - Vent-Free Fireplace InsertHoodScreenHeater Controls (Behind Panel)WATER VAPOR: A BY-PRODU

Strany 30

www.usaprocom.com7200069-01AAIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a conned space or unusually tight co

Strany 31

www.usaprocom.com200069-01A8DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONDetermining if You Have a Conned or Unconned Space4. Compare the maximum

Strany 32 - WARRANTY

www.usaprocom.com9200069-01AVENTILATION AIRVentilation Air From Inside BuildingAIR FOR COMBUSTION AND VENTILATIONOutlet Air Ventilated Attic Outlet A